CURD MILK HEATER MODULE Cap-3000 LPH
Basis of Design:
Product: Whole Milk, 16.5%., Capacity: 3000
LPH, Temp Program: 3-42 +_1 deg C.
Process Operation: Pasteurization temperature
control (by PID controller) and flow rate (by mechanical flow controller in
case of milk pasteuriser) will be automatic. Flow will be diverted
automatically with alarm if temp is below the past temp. Sequencing of
production, sanitisation and CIP will be manual. Detergent addition in the
balance tank and concentration monitoring will be manual. CIP flow rate will be
approximately 1.2 times of the product flow rate.
Utilities
Required (Approx):
Hot Water: 4500
Lph Approx.
Total power: 5
kW, (3.7 kW Prod. Pump, 1.1 kW HW Pump) 415V, 3 PH, 50 Hz
Process water:
5500 LPH during CIP
CIP flow: 5500
LPH Instrument Air, 6bar: 625 NL/Hr.
• The volume of
the storage (tank) for compressed air should approximately 6 times the required
capacity/h.
SPECIFICATIONS
& SCOPE OF SUPPLY
Sr. No
|
Description
|
Qty
|
1
|
Balance tank Capacity, 250 L, and
2 mm thick, MOC SS304, mounted on Frame and manhole cover. Product inlet, cup
type outlet and over flow port, CIP spray ball to clean tank during CIP, milk
diversion port, Float and high and low level socket with plug and tuning fork
type level sensors for giving audible alarm. If high level reaches, stop the
raw milk pump and stop feed pump in case of low level, inlet for water, etc.
Milk diversion line shall be connected on top thru no foam inlet to have self
draining facility of diverted milk.
|
1 no.
|
2
|
Feed pump SS sanitary
centrifugal type feed pump of adequate capacity & HEAD to take care of
1.2 times flow during CIP shall be fitted with VFD to Control flow rate of
6000 LPH. It shall be provided with flanged motor with hygienic mechanical
seal arrangement. The motor shall be EFF1, 3 Phase, 415 V +/-10%, 50Hz +/-5%,
TEFC, Squirrel cage with class #F” insulation with IP55 protection. The pump
and the drive motor shall be integrated together. The drive motor shall be
fitted with stainless steel SS304 arrangement for cable connection. Motor
completely cover with SS covers having louvers. Make: ALFA LAVAL
|
1 No
|
3
|
Variable frequency Drive with Flow
meter Frequency drive (Danfoss make) with DOL starter & magnetic flow
meter (E&H make) to control the product flowmeter.One No Flow meter to
control the hot water flow.
|
2 No.
|
4.
|
Plate heat exchanger PHE Model: MS6
SLI Frames: MS cladded with SS304 Plates: ALLOY 316/0.5 Thk Gaskets: NBR CLIP
ON No of sections: one Design temp: 110 deg C Design/test pr.: 6/8 Bar PHE
Pasteuriser will be designed considering the CIP cleanability and keeping the
CIP flow requirement which should be closed to the prod flow.
|
1 No
|
5
|
New Generation Hot water system
New Generation improved Hot water system will be THE based and will house a
Stainless steel expansion vessel and other safety devices to take care of the
volume expansion and increased pressure making the complete operational
safety. It consists of the following components:
• Tubular Heat Exchanger with
SS316 inner tubes an SS304 outer shell.
·
Specially developed Stainless
steel Expansion vessel, to take care of volume increase of hot water in the
system,
·
Uniquely designed Pressure relief cum Safety
Valve, to let excess water from the system and maintain required pressure, •
·
Air vent, to vent air from
the hot water system as it will disturb the Temperature control, •
·
Pneumatically controlled
Steam control valve, ...................... make with I/P converter and Air
filter/pressure regulator. •
·
Water make up valve, to
initially fill the system, internals in SS 304,
..............................make. •
·
Steam trap, float type, ................make,
•
·
Steam trap, by pass for
Sampson spirax, shut off valve •
·
Steam filter Y type strainer
•
·
Centrifugal pump all wetted
parts in SS316L, SMS connections with single shaft seal with motor.
• Centrifugal pump all wetted parts in SS316L, SMS with VF
connections with single shaft seal with motor.
|
|
6
|
Control panel. Automatic
controls shall be provided to ensure correct milk temperature. If required
temperature of the milk is not achieved the flow shall automatically be
diverted to balance tank with audible alarm and reset arrangement all the
instruments will be housed inside a self supporting dust, weather and vermin
proof enclosure made up of stainless steel confirming to AISI 304 and shall
have following components:
• MOC: SS 304, Duly pre-wired
and tested, & consists of the following Instruments and Controls:
• Temperature Indicating
Controller,
• Alarm/Hooter with `reset’
switch to announce diversion of milk
• Manual/Auto switches for
operating flow diversion valve.
• 7 Nos. Start/stop push buttons
with indicating lamps for process pump (milk pump, hot water pump etc.) &
motors
• 1 No ON/OFF lockable switch
with indicating lamp for incoming supply from `Mains’. .
• PID controller: Temperature
indicating controller showing actual temp and set temp. Of milk.
• Multi channel (6nos.) temp.
indicator for hot water and milk inlet & outlet, with data logging
facility and transferrable to computer .The controller shall automatically
tune to the set temperature requirements complete with I/P converter for
steam valve operations with electrically operated solenoid valve for air
supply to flow diversion valve. • Suitable DOL starter with VFD for the milk
feed pump & Hot water pump for controlling milk inlet & hot water
flow.
• Alarm hooter with reset push
button & indicating lamp for diversion milk.
• Suitable air filter cum
pressure regulating valve shall be provided on one side of the control panel
to bring down the air pressure to required level and to filter it.
|
|
7
|
Automatic Flow diversion Valve
Imported Unique Single Seat Valve, ......... make SDU45 with control unit,
with wetted parts in SS 316, EPDM seat with CIP arrangement of seat lift.
|
1 No
|
8
|
Manual diversion valve at the
Outlet of Pasteuriser Butterfly valve, ............ make for re-circulation
during production with CIP & Sanitation.
|
2 Nos.
|
9
|
Pressure Gauges –To monitor
Pressure at Raw Milk and Hot water inlet/outlet
|
4 Nos.
|
10
|
Thermo wells- Hot water outlet
|
1 No.
|
11
|
Temperature sensors .........make
(PT-100) with Temperature sensors and suitable length copper conductor ........
make shielded cables for all the Temp transmitters. Raw milk inlet to PHE
Heated milk outlet from PHE Hot water inlet to PHE Hot water outlet from PHE
Final product outlet after diversion valve Same to be followed for recording
on data logger
|
1 Set.
|
12
|
Manual regulating valve to
create back pressure at the temperature outlet product side.
|
1 No.
|
13
|
Interconnecting pipes and
fittings within Module All pipes are imported and fittings are ............
make to make the internal welding surfaces smooth and hygienic.
|
1 Lot
|
14
|
Technical documentations
Technical documentation consist of two sets of following: Equipment Layout
drawings Flowchart Instruction Manual Technical manual Heat exchanger
plattage drawing 2 set 13 Data Logger-Paperless Temperature Recorder Multi
channel (6nos.) temp. Indicator for hot water and milk inlet & outlet,
with data logging facility to transferrable to computer.
|
1 No.
|
|
Note : All the above components
will be installed on SS 304 SKID FRAME in compact aesthetic modular
construction except PHE pasteurise
|
|