BASIS OF DESIGN Unit
 Description: De-aerator/De-odourization System Capacity – 5000 l/h
Basis of Design: Product: Milk 16% TS
Process Operation: Dearation level control will be automatically controlled with the help of the SPC valve and the two pressure transmitter. The controls will be built into a control panel supplied with the module. De-odorizes module shall be stand alone PLC Controlled Utilities Required (Approx): Chilled water: 10000 LPH CIP flow: 8000 LPH Instrument Air, 6bar : 525 NL/Hr.
Internal SPECIFICATIONS & SCOPE OF SUPPLY   
Sr. No                                                                                                    Description                                         Qty
1 DEARATION Vessel DC 500 Chamber and cover in stainless steel 304construction specially rounded corners and internal sanitary finish. The bottom is in double wall construction for circulation of cooling water to avoid foaming of the product. This incorporates socket, SS spiral condenser, vacuum pump connection, chilled water inlet and outlet connection                                           1 No
2 Extraction pump Centrifugal pump, Alfa Laval Make, all wetted parts in SS316L, SMS connections with single shaft seal with motor of Crompton make.                                                                                 1 No
3 Vacuum Pump Vacuum pump in cast iron construction complete with auto drain valve and directly coupled motor pump is used for extracting noncondensable gases from de-aerator vessel   1 No
 4 Level Control System: Two Pressure transmitters to control level inside de-aerator. 1 set
5 Set of Valves: Valves for chilled water and cooling water                                                            1 Set
6 PHE To maintain the correct temperature at the inlet/outlet of the deaerator/de-odourizer along with vapour extraction system                                                                                                                                 1 Set
7 Control Panel • PLC control panel for accurate control of the parameters • MOC: SS 304, Duly pre-wired and tested, & consists of the following Instruments and Controls: • Temperature Indicating Controller, • Alarm/Hooter with `reset’ switch to announce diversion of Cream • Manual/Auto switch for operating flow diversion valve. • 7 Nos. Start/stop push buttons with indicating lamps for process pump (Cream pump, hot water pump etc.) & motors • 1 No ON/OFF lockable switch with indicating lamp for incoming supply from `Mains’.                                                                             1 No
8 Interconnecting pipes and fittings within Module All pipes are imported and fittings are SS316 Alfa Laval make to make the internal welding surfaces smooth and hygienic. Interconnecting piping to & fro from existing Cream pasteurisation module is also included in scope of supply 1 Lot
Note : All the above components will be installed on SS 304 SKID FRAME in compact aesthetic modular construction