Thursday, 20 June 2019

SPECIFICATION FOR SPRAY DRYER - I ( 100 Kg. / HR. evaporative capacity)


SPECIFICATION  FOR  SPRAY  DRYER  -  I  (  100 Kg. /  HR.  evaporative  capacity)

a.              Feed  rate (product) -  280 Kg. per  hour. at  48 %  T.S.  and  80 oC,  for  skimmed  milk.
                                          170 Kg. per  hour. at  48 %  T.S.  and  80 oC,  for  whole  milk.

b.         Product  out                                            110 Kg.  per  hour  with  4%  moisture, ( SMP)
c.          Design  Basis
             Plant  Altitude                                        565 Mtr.
Barometric  height                                 94.7 Pa  (710    mm  Hg)
Ambient  temperature                          20 deg. C.
Absolute  humidity                                0.010  kg. /kg.

             Cooling  Design
             Ambient  temperature                          40 deg. C.
             Absolute  humidity                                0.0252  kg. /kg.

D          Source of  heating
           Main  air  heater                                    I.       Steam  section.  20 oC  TO   180 oC  steam  at  15  bar,  total  load  105 kW.
                                                                                         620X620 FCE- 6ROWS,
                                                                               II.     Electric  section   180 oC  to  225 o C   total  load  30  kW.
                                                                                        Air  quantity  2200  kg / hr,
                                                                                        The  electric  section  should  be  designed  in  five  banks,  each  bank  of  6 kW,  with  a  facility  to  turning  on  or  off  each  bank  independently.

          SFB,  AIR  HEATER                                         Capacity  --  210  kg. /  hr,
                                                                                       Temp.  duty--  20  to  130  deg. C,
                                                                                        Steam  -- 8  bar  / 16  bar
                                                                                        Max.  pressure  drop  across  heater  --- 50  mmwc
                                                                                       Heater  type  is  fin-coil.  with  MS  tubes  and  aluminum  fins
                                                                                        Air  velocity  available  is  2.5  to  4 Mtr. per  sec,

         VFB,  AIR  HEATER                                         Capacity  --  75  kg. /  hr,
                                                                                       Temp.  duty--  20  to  130  deg. C,
                                                                                        Steam  -- 8  bar  / 16  bar
                                                                                        Max.  pressure  drop  across  heater  --- 50  mmwc
                                                                                       Heater  type  is  fin-coil.  with  MS  tubes  and  aluminum  fins
                                                                                        Air  velocity  available  is  2.5  to  4 Mtr. per  sec,
  e.        Chamber  --
             diameter---1.391  Mtr. x2 mm.                   Height ----     4.981 Mtr.
             Bustle  diameter  2.226 Mtr.                         Straight  portion  of  bustle --  390 mm.
             Bustle  angle ---  45deg.C                               Top  dia  ---   803  mm  dia, X  45 deg.
             Air  inlet   ---- 200 mm. dia,                           Air  exhaust    ---    110 mm.  dia   x   4 Nos.
             SFB,    dia ---505 mm,  height --   700 + 700  mm,
                                   out  let  --   150 mm.     
f.          Main  exhaust  cyclone  ---    1  Nos.
             Diameter    -------    944  mm.  Dia X  cone  angle ---  10  deg.  side,
             Size  of  inlet---  168  X  299  mm.
             Size  of  outlet---  266 Dia,
             vortex   --   596  Dia X  376  Dia  X  669  height,

g.          Fluid  bed  ---   1Nos.  (  VFVE - 0.3 -0.3 -2)
             Feed  rate  to  fluid  bed ---       
             Face   area  ---- 0.32  Mtr.  sq.     Motor - 600watt.

h.         BAG  HOUSE  ---  1  Nos.
             Dia  ---1.5  Mtr.  ID
             Inlet   ---   170  X   480  mmFilter
             Bags,  ---23  nos.  of  150  Dia,  X  1500  long,

i.                Air  supply  fan---
             3000  kg.  per  hour  at  550mm wg.  Air  inlet  temp. --   50  oC,
             Air  density  0.9826,
J           Air  exhaust  fan --
             3000 kg.   per  hour  at  550 mm wg, Air  inlet  temp. --   100  oC,
                Air  density  0.85,

 k.        Root  blower :                                                   AC -43  ,  of  key  compressors
                                                                                         100 kg.  per  hour   at   0.9  kg,  pressure.
                                                                                         Air  temp.  11 oC,

 l.          AIR  FILTER                                                   Efficiency  --  98%,
                                                                                        Air  velocity  required  2.5  to  4  Mt.,  per  sec.
                                                                                        Material  of  construction  of  filter  frame --   S.S.
                                                                                        Material  of  construction  of  filter   --  suitable  food  grade
                                                                                        Size  of  filter  ---610 X 610 mm,
                                                                                        Max.  pressure  drop  across  the  filter  50  mm wc. in  dirty  condition
                                                                                         Ax .  working  temp. --   80 o C.

m.        Dehumidifiers
             VFB  air  dehumidifiers                                  Capacity  340 kg .  per  hr.
                                                                                         Pressure  drop  across  entire  dehumidifier  max.  75 mmwc,
                                                                                        Air  velocity  available  is  2.5  to  4  Mtr. per  sec
                                                                                        Cooling  section  --  cooling  temp.  duty  40  to  7  deg. C  at  50%  inlet  humidity
                                                                                        (approx.  cooling  load  of  7  kW )
                                                                                        Medium  is  chilled  water  at  1  deg.  C
                                                                                        Construction  is  fin -coil  type  with  SS  tubes  &  Aluminum  fins
                                                                                        Surface  area  approx.  690  sq. Mtr.
                Heating  section                                            Heating  temp.  duty  7 to 11 deg.  C.
                                                                                          Medium  is  hot  water  /  candancate  at  40  deg. C.
                                                                                        Construction  is  fin -coil  type  with MS  tubes  &  Aluminum  fins
                                                                                        Air  velocity  available  is  2.5  to  4  Mtr. per  sec.

n.  Atomizing                                                                spray  nozzle  assembly
                                                                                        Delavan   Mini - SDX.
                                                                                        High  pressure  pump  --  Capacity  200  lph.
                                                                                        Delivery  pressure    --    350  bar.
                                                                                        Product  Viscosity   --  120  cp
                               
o.   Vibratory  sifter                                                      Capacity   ---   110  kg.  per   hr.
    
p.    Product  feed  pump  to  hi - pr.  Pump             Capacity  --200  kg.-  per  hr.
                                                                                         Head --   40  Mtr.

q.     Product  heater                                                     Capacity  --200  kg.-  per  hr.
                                                                                        tube  in  tube  type.

r.      Duplex  filter  for  concentrate.
         Pneumatic  hammers.
         Dampers.

s.   INSTRUMENTATION ---                                                                                         


sr./
Location
Instrument  Type
Range
Function
1.
After supply  fan
Pressure
0 to 750 mm wg.
Control supply  pressure
2
After dryer  air  heater
Temperature
0 to 300 deg.c
Control dryer inlet temperature
3
Lower part of  dryer
Pressure
-100 to 100 mmwg.
Control vacuum in dryer

4
Dryer outlet  duct
Temperature
0 to300 deg.C
Control  outlet temperature
5
Inlet to cyclone  w nxt
Pressure
-150 to 0 mm wg.
Indicate cyclone  differential
6
Outlet of cyclone w  prv
Pressure
- 350 to 0 mm wg.
Indicate cyclone  differential
7
Outlet of bag house w prv
Pressure
-750 to 0 mm wg.
Indicate bag  house differential
8
Outlet of bag house
Temperature
0 to 200 deg. C
Indicate temperature
9
Feed balance  tank
Level
0 to height of tank
Control level  and warnings
10
After product heater
Temperature
0 to 150 deg. C
Control  product  temperature
11
Before product filter w nxt
Pressure
0 to 10 bar
Indicate filter different + con

12
After product  filter
Pressure
0 to 10 bar
Indicate stofling pressure + con
13
After static fluid bed heater
Temperature
0 to 200 deg. C
Control inlet Temperature
14
Below static fluid bed plate
Pressure
- 50 to 300 mm wg.
Indicate fluid  bed Pressure
15
Above  static fluid bed plate
Pressure
- 50 to 300 mm wg.
Indicate fluid  bed level
16
Above  static fluid bed plate
Temperature
0 to 200 deg. C
Indicate fluid  bed  powder temperature
17
After external  fluid bed heater
Temperature
0 to 200 deg. C
Control inlet Temperature
18
Below  external  fluid bed  plate
Pressure
- 50 to 200  mm wg.
Indicate fluid  bed Pressure
19
After external  fluid bed heater
Temperature
0 to 100 deg. C
Control  inlet Temperature
20
Below  external  fluid bed  plate
Pressure
-50 to 200  mm wg.
Indicate fluid  bed Pressure
21
External fluid bed exhaust  duct
Temperature
0 to 100 deg. C
Indication  of VFB vacuum
22
Below external  fluid bed  plate
Pressure
- 50 to 200  mm wg.
Indication  of VFB vacuum


No comments: