Ultra
Osmosis System
Operation
Parameters:
· Feed:
60,000 L/hr of UF Permeate at 5.1% solids and
· Concentrate:
17,142 L/hr at 17.85% total solids 3.5: 1 Concentration
Factor
· Permeate: 42,857 L/hr
Equipment Specifications:
· Five
(5) RO recirculation loops
· Twenty-five (25) 8” 31 mil spacer UO
Membranes per stage
·
Five (5) membranes
per housing
· One hundred twenty-five (125) UO elements equal to 3,750 square
meters of membrane area.
Feed
System:
·One (1) 1,000 L enclosed balance
tank with man-way
·CIP Spray ball and drain valve
·Sample valve to be located on tank
·One (1) level control.
·One (1) temperature transmitter
·Six (6) divert valves
·One (1) four-port 4” divert plate
with proximity switches.
High Pressure Pump
System: Fristam Pumps
· One (1) Fristam FPR 1161s w/ 32
kw motors (feed pump)
· Two
(2) Fristam FM 522s w/ 100 kw motors (high pressure pumps)
· Five
(5) Centrifugal FPH 3542s w/ 37.5 kw motors (loop pumps).
· One (1) Fristam FPX 3522 with 7.5
kw motor (transfer pump)
· Five
(5) UO recirculation loops
· Five (5) pressure gauges
· Five (5) pressure transmitters to
measure boost pressure,
· One
(1) centrifugal recirculation pump per loop, (VFD’s will be
required
for each stage pump, not supplied)
· One
(1) Stainless steel vessel rack, 6 high, 6 wide
· Twenty-five
(25) 8” sanitary membrane housings
· Five
(5) inline coolers with control valves and temperature
probes,
· Five
(5) permeate Roto meters with collection piping and
return
lines to feed tank
· One
(1) heat exchanger with control valves for CIP.
· One
(1) seal water delivery system for high pressure pumps.
Concentrate Section:
Consisting of a 700 L enclosed balance tank
with manway and CIP spray ball. One (1) level control, One (1)
temperature transmitter and one (1) transfer pump 7.5 kw.
(VFD
required for this pump) Sample valve to be located on tank.
Permeate Section: 1,000 L balance tank, CIP spray ball, level
control, 7.5 kw transfer
pump
Control Section: The system is comprised of a central
control cabinet
with feed (CIP) balance tank, feeding a five (5) loop membrane
unit and controlled as follows:
One (1) Allen Bradley Control Logix PLC. One (1) operator
interface to be. Main
control panel includes warning lights and
emergency stop button. System concentration will be controlled
by means of a ratio with mag tubes in the
concentrate and feed line.
The control cabinet will
be NEMA 4X UL listed.
.