Boiler & Turbine Details
1
|
Type
|
Storker fired boiler with back pr.
Tubrine
|
2
|
Steam flow from boiler from 105deg. C
|
20000kg/hr
|
3
|
Steam temp. at boiler outlet
|
340 +/- 10deg C
|
4
|
Superheater outlet pr.
|
22 kg/cm2
|
5
|
Inlet pr. of turbine
|
21 kg/cm2
|
6
|
Total steam flow to inlet of turbine
|
7000 kg/hr.
|
7
|
Back pr.
|
3.5 kg/cm2
|
8
|
Bleed steam flow
|
-
|
9
|
Bleed Pressure
|
|
10
|
Steam temp. at inlet of turbine
|
330deg.C
|
11
|
Power generted
|
330KW
|
12
|
Feed Water temp.
|
105deg.C
|
13
|
Type of boiler
|
Indoor, Single drum water tube,
|
14
|
Fuel
|
Briquttes, Bagasses
|
17
|
Feed Pump - KSB
|
2 Nos.
|
18
|
Stoker
|
Hydrolic operated pulsating grate
stoker
|
19
|
FD Fan
|
Centrifugal direct drive, 50HP, pr.
200mm
|
20
|
ID Fan
|
Centrifugal direct drive, 125HP, pr.
225mm
|
21
|
Feed Pump
|
Multistage, 20m3/hr, 28kg/cm2 - 2
Nos.
|
22
|
Economiser
|
provided
|
23
|
Air Pre Heater
|
provided
|
24
|
Dust collector
|
cyclone type trema dust collector
|
25
|
LP & HP Dosing System
|
provided
|
26
|
Control Panel / MCC
|
provided
|
|
|
|
27
|
Turbine Details
|
|
|
Model
|
|
|
Maximum power output
|
330KW
|
|
Type
|
Velocity compounded, single stage
|
|
Design
|
Curtis (2 Rows)
|
|
Driven Equipment
|
Alternator
|
|
Turbine operating Speed
|
7000RPM
|
|
|
|
28
|
Tubine Inlet Conditions
|
|
|
Steam flow
|
7000 kg/hr.
|
|
Steam Pr.
|
21 kg/cm2(g)
|
|
Steam Temp.
|
330deg.C
|
|
Steam Rate
|
21.21 kg/KW-hr.
|
|
Steam Inlet size
|
4"
|
|
Steam Quality
|
Dry, free from any impurities
|
|
|
|
29
|
Turbine Outlet Conditions
|
|
|
Steam flow
|
7000 kg/hr.
|
|
Steam back pr.
|
3.50 kg/cm2 (g)
|
|
Steam temp.
|
210deg +/-10deg. C
|
|
Steam outlet Size
|
8"
|
|
Power output
|
330KW
|
|
Steam bleed pr.
|
|
|
Steam flow
|
|
|
Steam quality
|
|
|
|
|
30
|
Alternaotor
|
|
|
Make
|
|
|
KW
|
400KW
|
|
Voltage
|
415V
|
|
Voltage Variation
|
5%
|
|
Frequency
|
50Hz
|
|
Speed
|
1500rpm
|
|
Phase
|
3
|
|
PF
|
0.8 lagging
|
|
no. of poles
|
4
|
|
overload capacity
|
Star
|
|
Insulation
|
Class H
|
|
Overload capacity
|
10% overload for 1 hour in every 12
hours
|
|
Mounting
|
Horizontal foot mounting
|
|
Bearing arrangement
|
Double sleeve bearing
|
|
Duty
|
Continuous
|
|
|
|
31
|
Gear Box
|
|
|
Make
|
|
|
Input RPM
|
7000
|
|
Outpur RPM
|
1500
|
|
Gear Ratio
|
1 and 5 ratio
|
|
Lurbication
|
Forced
|
|
Type
|
Single reduction, parallel shaft,
helical type, foot mounted
|
|
Service Factor
|
1 and 5 ratio
|
|
Duty
|
Continuous input & output
|
|
Design standard
|
|
|
Class of accuracy
|
|
|
|
|
32
|
Control Panel
|
|
|
Type
|
Non Drawout type
|
|
Microprocesssor based relays with acb
|
Under voltage, over volatage, over
current, earth fault
|
No comments: