1. EVAPORATION SECTION

1.1. Feed balance Tank

The tank shall be provided with necessary connections for water & CIP lines. The tank is equipped with control valve for milk inlet, soft water supply at low level, CIP spray ball and sight glass. Flow plate shall be used for connection of milk line from pasteurized milk storage silos to feed balance tank of evaporation plant and CIP return lines.
Quantity : 1 No.
Capacity : 1KL
MOC : AISI 304
Type : Closed type, un-insulated.

1.2. Feed Pump

It shall be used for the transfer of milk from feed balance tank to Evaporation plant. It shall be provided with VFD (Variable frequency drive) and magnetic flow meter at the discharge end of pump for controlling the feed rate to the Evaporation plant.
Quantity : 1 No.
Capacity : To suit evaporator feed rate
MOC : Product contact parts - Impeller in AISI 316 and casing in AISI 304
Type : Centrifugal

1.3. Strainer (Duplex Filter)
It shall be provided with manual butterfly valves to remove the foreign suspended particle if any.
Quantity : 1 No.
MOC : AISI 304
Type : Pipe in Pipe

1.4. Dead Vapour Pre Heater

The milk from feed balance tank shall be preheated in dead vapour preheater by outgoing vapours from the separator of last effect calandria.
Quantity : 1 No.
MOC : AISI 304
Type : Shell and tube type

1.5. Low Thermophilic Pre Heater

The milk coming from Dead Vapour Preheater shall be preheated into low thermophilic preheater by the steam/vapour from thermo compressor. The plant shall be designed in such a way that product contact with metal surface at the thermophilic bacterial zone shall be avoided and design shall ensure steam economy by using thermo compressor.
Quantity : 1 No.
MOC : AISI 304

1.6. Steam filter (For Low Thermophilic Heater)

Steam filter shall be provided for filtration of live steam which shall be further injected in product. The filter shall be of 75 micron type (common for Low thermophilic and DSI) followed by 5 micron rating.
Quantity : 75 Micron – 1 No. and 5 Micron – 1 No.
Capacity : Suitable
MOC : AISI 304
1.7. Direct Contact Regenerative heater cum Flash Vessel

This shall be used to heat milk coming from the Low thermophilic preheater by the vapour generated from flash vessel. It shall also be used for flash cooling of the pasteurized product provided with specially constructed tangential inlet inclusive of CIP ring.
Quantity : 1 No.
Capacity : Suitable
MOC : AISI 304

1.8. Milk Pasteurizer – Direct Steam Injector

To heat the milk to the required pasteurization temperature by tangential injection of steam in an on-line piping system. It shall be equipped with de–superheating equipment & protected against over pressure by a pressure relief valve.
Quantity : 1 No.
Capacity : Suitable
MOC : AISI 304


1.9. Steam filter (For DSI)
Steam filter shall be provided for filtration of live steam which shall be further injected in product. The filter shall be 5 micron rating.
Quantity : 1 No.
Capacity : Suitable
MOC : AISI 304

1.10. Temperature treatment holder
It shall be used to hold milk for a required holding time. Selection of required holding time based on type of powder to be produced and as per the design requirement shall be done with manual swing bends.
Quantity : 1 Set.
MOC : AISI 304

1.11. Inline Filter
It shall be installed before the first effect Calandria for removal of solid particles from milk, if any. One no. of actuated butterfly valve shall be provided for drain.
Quantity : 1 No.
MOC : AISI 304

1.12. Calandria – Falling Film Type
The Calandria shall be of the vertical shell and tube type, specially designed for falling film evaporation, supported by a stainless steel skirt. The Calandria shall be equipped with:
Ø Specially designed liquid distribution system at the top
Ø Removable top cover, fixed with swing bolts
Ø Sight glass on shell to observe condensate flow and hand hole on skirt
Ø First effect Calandria shall be insulated with 50 mm thick mineral wool and cladded with 0.8 mm thick AISI 304 sheet in reverted construction.
Ø Suitable arrangement for proper CIP of Calandria

Quantity : 5 Nos.
MOC : AISI 304
Type : Self supported Shell & tube type falling film

1.13. Vapour Separator
Vapour separator connected with calandria shall be in an all welded construction. The separator is vertical cyclone type self-supporting and is equipped with sight glass and arrangement for CIP.
Quantity : 5 Nos.
MOC : AISI 304
Type : Self supported

1.14. Product Transfer Pumps

It shall be used for transfer of product through each pass of the calandrias of evaporation plant.
Quantity : 1 Lot
Capacity : Suitable
MOC : Product contact parts - Impeller in AISI 316 and casing in AISI 304
Type : Centrifugal with seal water arrangement

1.15. Concentrate Discharge Pump

It shall be used for transfer of milk concentrate from the last effect calandria to feed concentrate tanks of feed system for Spray drying plant.
Quantity : 1 No.
MOC : Product contact parts - Impeller in AISI 316 and casing in AISI 304
Type : Centrifugal with seal water arrangement

1.16. Condensate Pump
One no. of transfer pump shall be used for transfer of condensate from first effect calandria. Another transfer pump shall be used for transfer of condensate from remaining calandrias. In both the cases, supplier’s scope shall terminate at the pump discharge. Further collection, transfer, storage and use shall be in the scope of purchaser.
Quantity : 2 Nos.
Capacity : Suitable
MOC : AISI 304
Type : Centrifugal

1.17. De-superheating Arrangement
It shall consist of one no. of pump with desuperheating nozzle.
Quantity : 1 Set

1.18. Thermo Vapour Re-compressor (TVR)
The thermo compressor shall be provided for compression of vapour to a high temperature level by means of live steam.

The thermo vapour re-compressors can be operated in combination for various duty conditions. The thermo vapour re-compressors shall be provided with mineral wool insulation and 0.8 mm thick AISI 304 reverted cladding suitable for thermal insulation
Quantity : 1 Set
MOC : AISI 304

1.19. Vacuum Pumps
The vacuum pumps shall be used for the creating the vacuum into the evaporation plant. During start up both pumps shall in operation and during normal plant operation only one pump shall be kept under operation.

The housing & casing shall be in cast iron with AISI 304 impeller & shaft. It shall consist of floor mounted base frame in Mild Steel with directly coupled motor and cast iron non-return valve in suction line.
Quantity : 2 Nos.
Capacity : Suitable
Type : Water ring type with mechanical seal

1.20. Surface Condenser
Surface condenser shall be provided for condensing of discharged vapour from last effect calandria using cooling water with required inlet and outlet connections. It shall have provision for cleaning of tubes through CIP Liquid.
Quantity : 1 No.
MOC : AISI 304

1.21. Vapour Ducting
It shall be provided in welded construction for connection between vapour separators, calandrias, surface condenser and TVR etc.
Quantity : 1 Lot
MOC : AISI 304

1.22. Seal water System
Seal water tank (100 L) shall be located at height so that soft water shall flow at required pressure for seal cooling of process pump. The soft water return shall be collected in the seal water collection tank (100 L) kept near to process pumps. The water from the collection tank shall be transferred to Vacuum pumps through PHE chiller. The chilled water shall be used as a cooling media. The return water from the vacuum pump shall be drained off.
Quantity : 1 Set
Capacity : Suitable
MOC : AISI 304

1.23. Cooling Tower

Cooling tower shall be in FRP construction, having fixed spray nozzles; water distribution system and Poly Propylene fill pack for heat transfer. The cooling tower is fitted with a statically balanced axial flow fan having adjustable type non-corrosion FRP blades. The cooling tower has air inlet louvers and supporting hardware / MS structures are galvanized for long life and to withstand wind load.
Capacity : Suitable
Quantity : 1 No.
Type : Induced draught cooling tower made in FRP casing with water distribution system, fan & electric motor.

1.24. Cooling Water Pump

Type : Centrifugal type in CI construction.
Quantity : 1

2. Concentrate Recovery System

2.1. Concentrate Recovery Tank

Concentrate recovery tank shall be provided to recover solids both from evaporation and spray drying plant under emergency and during water flushing. The concentrate shall be suitably diluted by adding soft water into concentrate recovery tank.
Quantity : 1 No.
Capacity : 5 KL
MOC : AISI 304

2.2. Concentrate Transfer Pump

It shall be used to transfer diluted milk concentrate from the concentrate recovery tank to liquid milk processing section.
Quantity : 1 No.
Capacity : Suitable
MOC : Product contact parts - Impeller in AISI 316 and casing in AISI 304

2.3. PHE for concentrate cooling
It shall be used for chilling diluted milk concentrate before the transfer from concentrate recovery tank to liquid milk processing section using chilled water as cooling media. The diluted concentrate shall be chilled up to 10 Deg. C.
Supplier scope shall terminate at the outlet of PHE. Further transfer, use and collection shall be in the scope of purchaser.
Quantity : 1 No
Capacity : Suitable
MOC : Plates of AISI 316 with MS frame in AISI 304 cladded construction
Type : Plate heat



3. SPRAY DRYING PLANT

FEED SYSTEM

3.1. Feed Concentrate Tank
It shall be used as feed tanks for Spray drying plant. The tanks shall be equipped with CIP spray ball, agitator, level switch and feed nozzle.
Quantity : 2 Nos.
Capacity : 2 KL
MOC : AISI 304
Type : Un-insulated and Free standing

3.2. Water Balance Tank
It shall be used for supply of water during start up and shutdown of the plant and in case of interruptions in feed supply. The tank shall be equipped with low level switch.
Quantity : 1 No.
Capacity : 200 L
MOC : AISI 304

3.3. Booster Feed Pump
It shall be used for transfer of milk concentrate from feed concentrate tank to high-pressure pump through feed filter & concentrate pre heater.
Quantity : 1 No.
MOC : Product contact parts - Impeller in AISI 316 and casing in AISI 304
Type : Centrifugal

3.4. Feed Filter
It shall be provided with manual butterfly valves for removal of foreign particle, if any
Quantity : 1 No.
MOC : AISI 304
Type : Pipe in Pipe (Duplex)

3.5. Concentrate pre-heater
It shall be used for heating of milk concentrate to necessary feed inlet temperature to Spray dryer. The principle is essentially a tube in tube design, with the product flowing in inner tube in a single product channel. The milk concentrate pre heater shall be suitable for continuous operation of 20 hours without any intermediate CIP. It shall be inclusive of indigenous make equipment’s including support stand, hot water system (Pump & PHE) & steam control valve and interconnecting pipework.
Quantity : 1 No.
Capacity : Suitable to match with dryer feed rate

3.6. High Pressure Feed Pump cum Homogenizer
It shall be used to pump milk concentrate to the high-pressure nozzle atomizer. The high-pressure pump cum two stage Homogenizer shall be of the multi piston type. The pump shall be provided with necessary safety valve and local pressure gauge.
The speed of the pump shall be regulated by variable frequency drive.
Quantity : 1 No.
Capacity : Suitable

3.7. Feed pipes & fittings
For the concentrate leading from feed pump to atomizer complete with necessary bends and fittings. End connection to nozzle atomizer assembly shall be through flexible hose pipe.
Quantity : 1 Lot

ATOMIZER ASSEMBLY
Complete with set of nozzles, supporting unit, manifold & pneumatically operated valves.

3.8. Nozzle Atomizer
Quantity : 1 Set
MOC : AISI 304

3.9. Tools for Atomizer
Special tools for assembly of the nozzle atomizer & changing the nozzle orifice insert.
Quantity : 1

3.10. CENTRALISED COMMON AIR FILTERATION UNIT
Dryer air filtration shall be with two stage air filtration of EU4 & EU 7 grade. Dry/cool air shall be filtered (complete air required for the plant) prior to heating. The filter shall be of the dry cell type and panel shall have number of cells arranged for easy access and removal for cleaning inclusive of filter mats.
The air filtration system shall be only for the process air for drying chamber, air disperser neck cooling, fines return conveying air, integrated fluidized bed and Vibro Fluidizer.
There shall be a common air filtration room with required quality filtering media. There shall be sufficient opening in the room covered by SS wire mesh for sucking fresh air from outside of the building. For this purpose a fan shall be installed in the filtration room.
From the filtered air room suitable size SS ducting shall be laid for drawing of filtered air to the inlet of man supply fan..
Quantity : 1 Set

3.10.1 AIR FILTER (EU-4 & EU-7)
Air filter shall be of self-supported pocket type. The coarse filter units shall have pockets with frames and mounted in stainless steel housing. The filter units are removable for inspection, cleaning and replacement. Incl. of necessary transition ducting made of stainless steel.
Quantity : 1 Set
MOC : AISI 304

3.10.2 Common Air filtration - Fan
One No. of Fan shall be provided to maintain a slight over-pressure in the filter/fan room. It shall be coated with anti-corrosion paint. The speed of the unit shall be controlled through frequency converter.
Quantity : 1 Set
MOC : Mild Steel

DISPERSER COOLING SYSTEM
3.11. Supply fan for air disperser cooling
It shall be used for supply of air through steam air heater for air disperser cooling. The supply fan shall be provided with electric motor & flexible connections.
Quantity : 1 No.
MOC : Air Contact parts in AISI 304 construction with base frame in MS
Type : Centrifugal

3.12. Steam Air Heater for air disperser cooling
It shall be used for indirect heating of the air by means of dry & saturated steam. The heater shall contain AISI 304 tubes with Aluminium fins.
It shall have mineral type insulation with Aluminium cladding.
Quantity : 1 No.

DRYING CHAMBER ASSEMBLY
For mixing and establishing contact between the spray of atomized droplets and drying air to secure optimum conditions for rapid and controllable water evaporation and lenient drying, comprising of

3.13. Air Disperser
Air disperser is built into the roof of drying chamber and through which drying air flow is introduced into the drying chamber. The air disperser housing welded onto the ceiling of the drying chamber.
Quantity : 1 No.
MOC : AISI 304

3.14. Multi Stage Drying Chamber
This shall consist of cylindrical body with ceiling to support the air disperser and a conical part, designed to include built in stationary fluid bed. The air exhaust ducts shall be placed in the ceiling.

The drying chamber shall consist of cylindrical vessel with a conical bottom and top roof made of AISI 304 constructed, also the Chamber supporting ring shall in AISI 304 Construction and the chamber shall be on a framework of MS (Mild Steel) stiffeners.
The ceiling supports the air disperser. Ceiling shall have MS (Mild steel) structural with mineral wool insulation embedded in it and covered with MS (Mild steel) chequered plate.
The chamber assembly shall be provided with:
1) Switch for preventing critical vacuum and pressure in the chamber.
2) Imported Chamber door

Quantity : 1 No.

3.15. Insulation for Drying Chamber
The Cylindrical portion & cone of drying chamber shall be insulated with 75 mm thick resin bonded mineral wool of density 100-120 kg/m3 to prevent the heat loss and conductive working environment. The insulation shall be cladded with 0.8 mm thick AISI 304 sheet in riveted construction wherever required to prevent heat loss and comfortable working environment.
Quantity : 1

3.16. Integrated Fluid Bed
For secondary drying of product, designed and mounted on the conical part of the drying chamber.
The fluid bed shall consist of housing divided in an upper product part and a lower air plenum by a flex plate. The dividing sheet shall be self-supporting and provided with inclined perforations providing an even powder flow and a fluidized powder layer.
The fluid bed shall be insulated with mineral wool, and furnished with inspection and cleaning access, CIP nozzles and powder outlet arrangement.
Quantity : 1 No.
MOC : AISI 304

3.17. Rotary Valve
It shall be easy slide type used to form an air lock within the passage of powder. It shall consist of housing, rotor and a motor with gearbox.
Quantity : 1 No.
MOC : Product contact parts in AISI 304

3.18. Product Duct

For product discharge from the drying chamber to Vibro Fluidizer
Quantity : 1 Lot
MOC : AISI 304

3.19. Electromagnetic Hammers on Chamber

It shall be provided on the outside of the drying chamber to minimize deposits on the wall.
Quantity : 1 Lot

HOT AIR SYSTEM FOR DRYING PLANT
3.20. Spray Drying Supply Air Fan
It shall be used for supply of air to spray drying chamber through steam heater. The supply fan will be provided with variable frequency drive to maintain the required quantity of hot air in the drying chamber.
Quantity : 1 No.
MOC : Air Contact parts in AISI 304 construction with base frame in MS
Type : Centrifugal

3.21. Steam Air Heater

It shall be used for heating the process air by means of dry saturated steam. The steam air heater shall be provided with AISI 304 casing with AISI 304 tubes with Al fins. The heater shall be divided into two sections, one for steam and another for pre-heating the drying air by means of condensate. The heater shall be complete with all intermediate steam and condensate piping, steam stop valve, pressure gauge, steam trap.
It shall have mineral type insulation with Aluminium cladding.
Quantity : 1 No.

HOT AIR SYSTEM FOR STATIC FLUID BED
The system shall comprise of following:

3.22. Supply Air Fan for SFB
It shall be used for the supply of air to static fluid bed. The supply fan shall be provided with flexible connections and electrical motor.
Quantity : 1 No.
MOC : Air Contact parts in AISI 304 construction with base frame in MS
Type : Centrifugal

3.23. Steam Air Heater
It shall be used for heating the process air by means of dry saturated steam. The steam air heaters shall be provided with AISI 304 casing with AISI 304 tubes with AL fins. The heater shall be divided into two sections, one for steam and the other for pre-heating the drying air by means of condensate. The heater shall be complete with all intermediate steam and condensate piping, steam stop valve, pressure gauge, steam trap.
It shall have mineral type insulation with Aluminium cladding.
Quantity : 1 No.

AIR EXHAUST SYSTEM
3.24. Cyclones
It shall be provided for efficient separation of powder carried from the drying chamber by the outgoing air. Differential pressure transmitter shall be provided across both the cyclones.
Quantity : 2 Nos.
MOC : AISI 304

3.25. Electromagnetic Hammer on Cyclones
Provided on the outside of the Cyclone to minimize powder deposits on the wall.
Quantity : 2 Nos. (1 no. on each cyclone).

3.26. Exhaust Fan
It shall be provided with frequency drive to maintain the vacuum inside the Spray drying plant.
VFD for exhaust fan shall be IP 54.
Quantity : 1 No.
MOC : MS (Mild Steel)
Type : Centrifugal

FINES RETURN SYSTEM
For continuous transport of fines from cyclones to the drying chamber / Vibro fluidizer for agglomeration.

3.27. Roots air blower
It shall be used for supply of air under pressure to convey the fines return to drying chamber. It shall consist of safety valve, non-return valve, pressure gauge and electric motor. It shall be provided with acoustic enclosure.
Quantity : 1 No.
MOC : Air Contact parts in AISI 304 construction with base frame in MS.

3.28. Blow through Valves
It shall be used for feeding milk powder to the fines return duct from cyclone outlet. It shall consist of electric motor & solenoid valve to provide the compressed air for cleaning of blow through valve. It shall be easy slide type.
Quantity : 2 Nos. (1 no. below each cyclone)
MOC : Product contact parts in AISI 304

3.29. Diverter Valve
It shall be used to divert milk powder either to drying chamber or to discharge end of Vibro fluidizer. It shall manual type valve.
Quantity : 1 No.
MOC : Product contact parts in AISI 304

3.30. Conveying piping for fines return

It shall be used to return fines from cyclones to the drying chamber. It shall be provided with complete with necessary bends & fittings.
Quantity : 1 Lot

VIBRO-FLUIDIZER ASSEMBLY
3.31. Vibro Fluidizer Supply Air Fan
For supplying air to the Vibro fluidizer. The fans shall be statically and dynamically balanced and shall be provided with electrical motor.
Quantity : 3 Nos.
MOC : Air Contact parts in AISI 304 construction with base frame in MS
Type : Centrifugal

3.32. Vibro Fluidizer Steam Air Heater
For heating the process air by means of dry saturated steam. The steam air heaters shall be provided with AISI 304 casing, AISI 304 tubes & Al fins.
The heater shall be complete with all steam and condensate piping, steam stop valve, steam trap.
It shall have mineral type insulation with Aluminium cladding.
Quantity : 2 Nos.

3.33. Vibro Fluidizer Air Dehumidifier
It shall be used for dehumidification of process air using chilled water as cooling media & steam as heating media. It shall be provided with AISI 304 casing, AISI 304 tubes & AL fins. It shall consist of necessary valves and piping. It shall consist of two sections. In the first section, air shall be cooled by chilled water. In 2nd section, cooled air shall be heated by steam.
It shall be complete with all intermediate steam and condensate piping, steam stop valve, pressure gauge, steam trap.
It shall have mineral type insulation with Aluminium cladding.
Quantity : 1 No.
MOC : AISI 304

3.34. Air Fine Filter – (HEPA FILTER – EU-12 GRADE)

It shall be provided for the cooling section of the Vibro Fluidizer and fines return line. MOC of filter housing, inlet flange, outlet flange, Filter frame shall be AISI 304 with base frame in MS.
Quantity : 1 No.
Type : EU 12

3.35. Vibro Fluidizer
The Vibro fluidizer consists of drying, conditioning & cooling section. It consists of vibrating tubular housing divided into an upper and a lower part by an imported flex plate. Vibro fluidizer shall be made as per sanitary standards.

Air is blown into the lower part (Plenum chamber) for fluidizing & drying of the product which flows through the upper part. An Imported vibrator element mounted in the lower part of the housing shall generate the vibrations. To prevent vibrations being transferred to surroundings the Vibro-fluidizer shall be mounted on spiral springs on a mild steel frame. The upper part of the Vibro-fluidizer shall be provided with inspection doors. The outlet air of Vibro Fluidizer shall be fed to cyclones through suitable ducting.
Quantity : 1 No.
MOC : AISI 304

3.36. Rotary Valve
It shall be easy slide type used to form an air lock within the passage of powder. It shall consist of housing, rotor and a motor with gearbox.
Quantity : 1 No.
MOC : Product contact parts in AISI 304

3.37. Powder Sifter
It shall be used for screening the milk powder and separating out the lumps from final product. The MOC of vibrating screen with powder contact parts made of AISI 304 and other parts of painted MS. It shall be provided with top cover and flexible connections inclusive of motor.
Quantity : 1 No.

3.38. Air Ducting
The ducting shall be provided wherever necessary for air supply to drying chamber including air disperser, Static Fluid bed, Vibro Fluidizer, and exhaust. It shall be provided with necessary bends, transition pieces and dampers.
Quantity : 1 Lot.
MOC : AISI 304

FIRE EXTINGUISHING SYSTEM
Fire Extinguishing System shall be used for the safety of Spray drying plant and operators in the event of an accident occurring in spite of the precaution measures taken in the design of the plant to minimize the risk.

3.39. Explosion vent
It shall be diaphragm type, placed in the cylindrical part of the drying chamber. It shall be designed to burst at a certain air pressure in order to protect the chamber. The diaphragm is fixed between flanges with bolts. To be vented into safe area.
Quantity : 1 Set

3.40. Over-Pressure Duct
It shall be from explosion vents of drying chamber to outside of building through openings.
The duct is provided with inspection opening and the maximum length of the duct is 3 meters.
Quantity : 1 No.
MOC : AISI 304

3.41. Fire Extinguishing System for Drying chamber & Vibro fluidizer

For drying chamber
It shall be provided for the drying chamber, designed for water hosing of the total inner surface.

The system comprises a set of nozzles placed in the chamber cylinder, connected to a ring-pipe with main valve and drain valve. The nozzles are flush with the inner surface during normal operation and are opened by the water pressure when the system is activated.
A PT100 temperature sensor is placed in the chamber outlet duct for detecting and signaling the pre-set temperature rise to the control panel. The temperature sensor is hardwired to a control panel comprising a monitoring relay with High and High High alarms.
The system is designed for a water supply of approx. 140 l/min. per nozzle at a dynamic pressure of 2 bar g at the nozzle in operation.
Quantity : 1 No.

For vibro fluidizer
It shall be for the VIBRO-FLUIDIZER™, designed for water hosing of the inner surface. The system comprises nozzle with main valve and drain valve. The nozzle is flush with the inner surface during normal operation and will open by the water pressure
A PT100 temperature sensor is placed in the VIBRO-FLUIDIZER™, outlet duct for detecting and signalling the pre-set temperature rise to the control panel. The temperature sensor is hardwired to the control panel comprising a monitoring relay with High and High High alarms.

The system is connected to the control panel.
The system is designed for a water supply of approx. 140 l/min. per nozzle at a dynamic pressure of 2 bar g at the nozzle in operation.
Quantity : 1 No.

3.42. Fire Control Panel

It shall be used for control of the fire extinguishing system, made of lacquered mild steel and to be mounted on the wall. The panel contains controls for manual and automatic supervision and activation of the system, including acoustic and visual alarms for water, compressed air and power supply.
Quantity : 1 No.

The powder plant will be put in operation mode only when Overhead tank is filled with water. The system will receive the signal from the powder plant control panel in case plant is subjected to temperature beyond the set value. The ring main shall always remain under set limit of pressure values and it will maintain the pressure throughout the operation of the powder plant.

Overhead tank of suitable capacity & water at pressure of 2 Bar g at the inlet of fire nozzle shall be made available by purchaser.

3.43. Fire Water Piping to feed to Ring Main of Dryer

From Overhead tank to ring main system of spray drying plant
Quantity : 1 Lot

4. CIP ANCILLARIES:

4.1. CIP Return Pumps

One no. of pump shall be connected at the outlet of the pig tank and another at the outlet of feed concentrate and recovery tank (Self Priming type) for CIP return.
Quantity : 2 Nos.
Capacity : Suitable
MOC : Working parts - Impeller in AISI 316 and casing in AISI 304
Type : Centrifugal type

4.2. Cleaning Turbine
The cleaning turbine shall be used for cleaning of drying chamber. It shall be of rotary type with hose and manual winch.
Quantity : 1 No.
MOC : AISI 304

4.3. CIP Nozzle
It shall be used for CIP of Vibro Fluidizer, ducts, SFB and Cyclones.
Quantity : 1 Lot
MOC : AISI 304
Type : Retractable

4.4. Pig Tank
It shall be used for collection of CIP solution and returning it to CIP tanks / drain.
Quantity : 1 No.
Capacity : 1 KL
MOC : AISI 304

5. Automation

5.1. Automation ( Evaporation Plant)

PC-PLC based control system shall make various operations in milk Evaporation plant automatic (Through PLC). Operations as listed below shall be carried out automatically. However, manual interventions shall be needed in case of alarm conditions are reached or if there are manual activities required to be carried out (like connecting swing bends, hoses, dumping/unloading, damper/valve setting etc., whichever applicable).

Evaporation section
The following process operations are considered automatic (Through PLC) in Evaporation section:
Ø Steam pressure monitoring & Control for Thermo compressor
Ø Steam pressure monitoring and PID control loop based on DSI temperature
Ø Vacuum monitoring for last effect & Control of Cooling water flow to Condenser based on Vapour Temperature of Last effect.
Ø Level control for Feed Balance Tank
Ø Temperature control of Low Thermophilic Heater
Ø Feed flow monitoring & flow control loop implemented through VFD Driven feed pump & flow meter
Ø Final concentrate density monitoring based on density transmitter
Ø Automatic start / Stop of Motors in evaporator section. The status of each motor would be available on the screen.

In addition to above, the following indication / alarms shall be displayed & monitored on SCADA screen:
Ø Condensate conductivity measurement, monitoring & Diversion.
Ø Low level alarms for Seal water tank and Feed balance tank

The other operations automated through PLC system are:
Ø Start-up
Ø Vacuum on
Ø Heating
Ø Circulation
Ø Stabilization
Ø Production
Ø CIP

Manual Interventions:
Ø Feed Inlet to Evaporator Feed balance tank.
Ø Changing of holding tubes i.e. for selection of holding time.

5.2. Automation (In Spray Dryer)

Dryer section
PC-PLC based control system shall make various operations in Spray drying plant automatic (Through PLC). However, manual interventions shall be needed in case of alarm conditions are reached or if there are manual activities required to be carried out (like connecting swing bends, hoses, dumping/unloading, damper/valve setting etc., whichever applicable).
The following process operations are considered automatic in dryer section:

Ø Pre-heating temperature of feed concentrate to Spray dryer through concentrate preheater.
Ø Feed flow control through HPP by frequency drive based on Dryer outlet temperature.
Ø Booster Feed pump with frequency drive and pressure transmitter to ensure required head at the suction of HPP.
Ø Steam control based on inlet Air temperature to Dryer.
Ø Steam control based on inlet Air temperature to SFB.
Ø Steam control based on inlet Air temperature to heating section of the VF.
Ø Chilled water control loop for Dehumidifier of VF section.
Ø The drying chamber pressure monitoring & control through Frequency drive at Exhaust fan.
Ø Remote start / Stop of Motors in dryer section. The status of each motor would be available on SCADA screen

The other operations that shall be automated by PLC system are
Ø Sequential start-up
Ø Sequential shut down

The following operations shall be done manually / operator.
Ø Control of Manual Valves & Air flow dampers
Ø Control of air flow for false air by Manual damper if required.

5.3. Fire extinguishing system

Following operations, Indications / alarms for fire extinguishing system through PLC shall be provided:

Ø Dryer outlet temperature High, High- High alarm & Solenoid operations for fire water flow based on alarm conditions.

The logic for fire system operation conditions including start /stop of fire water pump & /or opening of fire water valve shall be through fire control panel.

5.4. Programmable Logic Controller (PLC) ( 1 Number - Common for both - Dryer and Evaporator)

The proposed PLC based system shall have following main features as:
Ø Digital I + O : Point IO module Type.
Ø Analog I + O : Point IO module Type.
Ø Programme Memory : shall be suitable for ladder logic
Ø All the Field Instruments shall be connected to Smart JB type RIO Panels. Instruments will be connected directly to Terminals of I/O Module.

5.5. Operator Station (OS)

The proposed operator station shall be as follows:
Computer with 22" inch colour monitor for the purpose of SCADA
(Supervisory Control & Data Acquisition Station)
Operator station comprises of:
Ø 2nd generation Intel i5 processor, 2.5GHz PC, PC-IDE, 4 GB RAM,1 MB Cache, 160 GB HDD, standard Keyboard & mouse With Windows 7
Ø Run time software for 2 operator station.
Quantity : 2 Nos.

Main features that shall be made available in workstation are
Ø Process diagrams in multiple colors in pixel based graphics, complete with Trend curves, bar graphs, real-time values of process parameters, latest status of all equipment and 3 latest alarms.
Ø Real-Time Trending of process parameters for analysis.
Ø Automatic printing of alarms, events
Ø Prioritized data acquisition cycles. Instantaneous operator-command execution.

5.6. Printer
LaserJet colour suitable for A4 :1 No.

5.7. Network Hardware
UTP / STP Cables : 1 Lot

Field Instruments, Control Valves and Accessories
Field Instruments shall be suitable for area in which these are located. In general, field instruments shall be weatherproof, dust tight and corrosion resistant with Protection Class IP-65. Field instruments shall be suitably mounted, supported and terminated in local junction boxes. All field instruments are hardwire type (4-20 mA, 24 v DC signal) & connected to automation system through Junction Box / RIO panel in the field.

6.1. Pressure Transmitter
The transmitters shall be provided as per requirement for process & utility .The hard wired signals (4-20 mA) shall be connected with automation system through remote I/O panel in field.
Proper sanitary type mounting arrangement shall be provided for installation of the sensors in various tanks/ pipelines, suitable for Dairy application. Tri-clamp type sanitary mounting arrangement shall be provided for the sensors to be installed in pipelines & for Non sanitary type application ½ “NPT threaded connection shall be provided.
Measuring ranges of transmitters shall be selected in such a way that the rated value of the measuring variables appears at approx. 50-80% of the span.
The sensing elements and internal parts shall be constructed with AISI 316.
Quantity : 1 Lot

6.2. Pressure/Temperature Gauge
Process gauges shall be provided for local indication on all utility lines & process tanks (as necessary).
Pressure gauge sensing element shall be Bourdon/Bellow/ Diaphragm type in general depending upon the process condition. Direct reading Pressure/Differential Pressure gauges shall be used of SS 316 sensing element and AISI 304 movement material.
Local temperature measurement shall be done bi-metal Temperature gauges. Temperature gauges may be direct mounted type (every-angle). The sensing element shall be of SS 316 for temperature gauges.
Quantity : 1 Lot

6.3. Temperature element with transmitter

All Temperature Sensors Elements shall be of Duplex type with SS 316 sheath, suitable for area in which these are located. Pt-100 Resistance Temperature Detector (RTD) shall be used.
RTD heads shall be via cast aluminium suitable for head mounted temperature transmitter mounting, with chain holder, shall be of the waterproof type, gasketed cover and stainless steel chain. Screwed covers shall be used.
Proper sanitary type mounting arrangement shall be provided for installation of the sensors in various tanks/ pipelines, suitable for Dairy application. Tri-clamp type sanitary mounting arrangement shall be provided for the sensors to be installed in pipelines.
The temperature transmitters shall be provided as per requirement for process & utility having best accuracy/reliability, as available in the market and the hard wired signals (4-20 mA) shall be connected with automation system through remote I/O panel in field. The transmitters shall head mounted & blind type.
Quantity : 1 Lot

6.4. Control Valves
Control valves of required turn down for process & utility application shall be provided having reliability & accuracy, the conventional E/P positioner shall be provided with hard wired signals (4-20 mA) signal i/p. The CVs shall be connected with automation system through PLC Remote I/O panel in the field.
Quantity : 1 Lot

6.5. Motors
Quantity : 1 Lot

6.6. Instrument Hardware
All type of instruments fittings & pneumatic fittings shall be provided for proper installation & operation.
Quantity : 1 Lot

6.7. Control Cables , Cable trays & Cable Glands
Quantity : 1 Lot

Level instruments
6.8. Level Switch
The level switches shall be tuning fork type (or suitable type as per process requirement) for all process & CIP applications. The hard wired signals (24 V DC) shall be connected through PLC Remote I/O panel in the field.
Quantity : 1 Lot

6.9. Mass / Density Meter
The flow sensors shall be sanitary type & suitable for Dairy application.
The Mass flow meter envisaged shall be Coriolis twin curved tube type. The Mass flow meter shall be capable of measuring mass flow rate, density, temperature, volumetric flow rate and totalized flow.

The flow tube/wetted parts material shall be SS 316 / SS 316L or as per the requirement of process fluid. SMS type process connection may be used for the mass flow meters.
Digital display of mass flow rate, density, temperature, volume flow rate as well as totalized flow shall be provided.

The flow meters shall be smart type of required turn down capacity having required diagnostic features with separate local display unit & the hard wired signals (4-20 mA) shall be connected with automation system through PLC Remote I/O panel in the field. The transmitters shall have field diagnostic / configuration facility. The flow meters shall be configurable from the in the field. Accuracy shall be +/-2%.
Quantity : 1 No.

6.10. Magnetic Flow meter
The flow tube material shall be of SS-304 with PTFE/PFA lining. The electrode material shall be SS 316L depending upon process condition. In general, SMS type process connection may be used for magnetic flow meters for sanitary application & for non-sanitary application flange type process connection shall be provided. The flow sensors shall be sanitary type & suitable for Dairy application.
Accuracy of magnetic flow meter shall be plus or minus 0.5 %of measured flow rate or better. Digital display of flow rate as well as totalizer display shall be provided.
The flow meters of required turn down capacity shall be smart type having required diagnostic features with separate local display unit & the hard wired signals (4-20 mA) shall be connected with automation system through PLC Remote I/O panel in the field. The transmitters shall have field diagnostic / configuration facility in field in field.
Quantity : 1 No.

6.11. Conductivity Transmitter
The conductivity transmitters of required turn down capacity shall be used for measuring concentration of CIP chemicals/ milk solid TS based on conductivity measurement having best accuracy & reliability suitable for Dairy application, as available in the market. SMS type process connection may be used for the sanitary type CTs. The conductivity transmitters shall have separate field display (digital) unit with hard wired (4-20 mA) signals & field diagnostic/configuration facility. Connectivity with automation system shall be through PLC Remote IO panel in the field.
Quantity : 1 Set

6.12. Instrument signal Cable
Instrument cable shall be of multi-stranded annealed plain copper conductor, extruded PVC type A insulated. Overall screened with Al. Mylar tape .Extruded PVC ST1 inner sheath unarmored / armored. Extruded PVC type ST1 outer sheathed instrument signal cables Min. Size of the instrument cable shall be 0.75 sq.mm.
Quantity : 1 Lot

6.13. Cable Tray
Cable trays shall be AISI 304 mesh type for powder plant with AISI 304 conduit / tray drop. Necessary accessories of cable trays such as coupler side plates for joining cable trays, bends, riser, inside riser, tee etc. shall also be supplied. Cable glands shall be provided at both ends of armored/ unarmored cables.
Quantity : 1 Lot

7. ELECTRICAL DISTRIBUTION SYSTEM

7.1. Motor Control Centre
The purchaser shall provide power to MCC.
The incoming and outgoing feeders from the MCC in the electrical control room shall have all the feeders’ entry & exit from the top.
Quantity : 2 Nos.

Specification
The motor control centre shall be completely dust & vermin proof conforming to IP 42 standard and shall be fixed non draw-out type compartmental / Wardrobe type construction. The MCC would receive, control & distribute electrical power at 433 V, 50 Hz AC to all electrical loads to be connected in drying plant. MCC will be manufactured as per latest ISI specifications, Indian electricity rules.

Type
The MCC shall be suitable for Indoor Installation. It would be fabricated as per detailed specification described below.

Bus bar rating
The bus bars shall be made from high electrolytic Aluminium. Conforming to grade E91E of IS 5082 with 0.8 Amp. / sq.mm current.
The bus bar shall be capable of carrying 1.2 times of full load current.

Feeders
Feeders up to 63 A will be protected by proper 3 pole /4 pole MPCB or Switch Fuse units, 63 Amp to 630A with MCCBs and 800A and above will be protected by Air Circuit Breakers
The Incomer shall have 3-phase 4-wire energy meter / multifunction meter with necessary Indications and CT's and phase Indication lamps. For Incomer of the panel, the rating of the switchgear shall be 1.2 times of rated full load current of connected load of the panel.
All motor feeders above 10HP shall have Star-delta starters and up to 10 HP shall have
DOL Starters.

7.2. Power Cables (LT)
Power cables for use on 415 V system shall be of 1100 volt grade, Aluminium / Copper conductor, XLPE insulated, XLPE sheathed, armoured and overall XLPE sheathed, strictly as per IS: 1554 (Part I) - 1976. Unarmoured cable to be used for vibrating equipment’s & only if specifically mentioned in schedule of quantities. Up to 12.5 hp 2.5 sq.mm copper conductor Armored cable & above12.5 hp Aluminium conductor Armored cable shall be used. Min size of copper conductor shall be 1.5 sq.mm
Quantity : 1 Lot

7.3. Control Cables (LT)
Control cables for use on 415 V system shall be of 1100 volt grade, Copper conductor, PVC / XLPE insulated, armoured and overall PVC sheathed, strictly as per IS: 1554 (Part I) – 1976 / IS 7098.
Size of copper conductor shall be 1.5 sq.mm
Quantity : 1 Lot

7.4. Cable Trays
These shall be mesh type, heavy duty, inward bend shape, manufactured from AISI 304. Width of cable tray shall be as per the requirement.
Necessary accessories of cable trays such as coupler side plates for joining cable trays, bends, riser, inside riser, tee etc. shall also be supplied.
Quantity : 1 Lot
MOC : AISI 304

7.5. Local Push Button Stations
The push button station shall be made in AISI 304, will be provided with Mushroom head emergency stop push buttons near the motor in field.
Quantity : 1 Lot

7.6. Junction Box
Quantity : 1 Lot
MOC : AISI 304

7.7. Variable Frequency Panel & Hammer Panel.
Quantity : 1 Set

a) VFD Panel Specifications:
Type of Panel : Self standing, Wall mounted, straight vertical
Degree of protection : IP 42