Milk Chiler – 20KLPH
Specification
Thermal data
hot
side cold side
Media: Whole milk Water
Heat
exchanged: 132.94 kW
Mass
flow: 20613 40078 kg/h
Volume
flow: 20.00 40.00 m³/h
Temperature
inlet: 10.00 1.50 °C
Temperature
outlet: 4.00 4.33 °C
Pressure
drop: 333 977 mbar
Working
pressure inlet: 3.00 3.00 barg
Product
properties
Density:
1030.6423 1001.9410 kg/m³
Heat
capacity: 3869.77 4224.25 J/kgK
Thermal
conductivity: 0.53229 0.56502 W/mK
Dyn.
viscosity inlet: 0.002738 0.001701 kg/ms
Dyn.
viscosity outlet: 0.003303 0.001555 kg/ms
Unit
Data
Heat
transfer area (total / per unit): 11.83 m²
Number
of plates (total / per unit): 72
Plate
thickness: 0.50 mm
LMTD: 3.87 K
Plate
material: AISI316
Gasket
material / Gasket type: NBR glueless
Internal
flow (passes x channels): 1 x 35 1 x 36
Material
pressure plates / surface: CS, SS-304
claded
No comments: