Data Sheet of Bag Filter- 24000m3/hr.
DESCRIPTION
|
Specification
|
Application
|
Boiler
Flue Gases
|
Firing type
|
AFBC
|
Fuel
|
100%
Indian Coal
|
Dust To be handled
|
Flyash
|
Air Flow rate
|
24000
Am3/Hr
|
Flue Gas Temp. (Min.) Deg C
|
170
|
Flue Gas Temp. (Max.) Deg C
|
220
|
Gas Pressure at Bag Filter Inlet mmwc
|
-200
|
Inlet Dust Load gm/Am3
|
50
|
Design Pressure (Inc. Wind Load) mmwc
|
±500
|
Recommended Air to Cloth ratio-
m3/Min/m2
|
1.1
|
Maximum Outlet Dust Emission Required
mg/Nm3
|
50
|
DESCRIPTION
|
THERMAX
|
Type of Filter
|
Pulse
Jet
|
Filter Mounting
|
Structure
|
Gas Entry
|
Casing
|
Pressure Difference across Filter
|
175 mmwc
|
Maximum Outlet Dust Emission mg/Nm3
|
50
|
Bag Material
|
Imported
Fiber Glass
|
Offered Bag Height (m)
|
3.6
|
Flue Gas Temp. (Max.) Deg C
|
220
|
Required Filtration Area (m2)
|
364
|
Offered Filtration Area
|
367.08
|
offered air -to-cloth ratio
(m3/min/m2)
|
1.090770404
|
Filter Model
|
|
Number of Bags Offered (No.)
|
210
|
Number of Solenoid Valve
|
15
|
Filter Casing
|
3mm
thick- IS 1079 Gr O
|
Filter Tube Sheet
|
5mm
thick-IS 2062 Gr A
|
Filter Top Cover
|
3mm
thick- IS 1079 Gr O
|
Filter Hopper
|
5mm
thick-IS 2062 Gr A
|
No. of RAV
|
1
|
Gases by-pass system
|
Auto on
high Temp.
|
No comments: